Diagnostic value of OCT for primary glaucoma: a meta analysis

Shan Liu, Xiang-Long Yi
2014 Guoji Yanke Zazhi  
AIM: To analyze the the ability of optical coherence tomography(OCT)in diagnosis of primary glaucoma through evidence-based medicine,the application of a variety of evaluation and statistical analysis model, provide a reasonable selection of reference to clinicians diagnose glaucoma diagnostic method.METHODS: The method according to Cochrane systematic reviews, systematic and comprehensive literature was searched PubMed, Web of Science, Medalink, CNKI, CBM, Wanfang Data. Collect all OCT
more » ... diagnostic test, the quality assessment of diagnostic accuracy studies(QUADAS)items were used to assess the quality of the included studies. The Meta-Disc software was used to analyze the data.RESULTS: A total of 16 trials were included, The results of Meta-analyses showed that the summary sensitivity, specificity and 95% CI were 0.86(0.84~0.88), 0.90(0.88~0.92). The SROC area under curve(AUC)was for 0.9517.CONCLUSION: OCT for diagnosis of primary glaucoma has higher sensitivity and specific degree, has great value in clinical application.
doi:10.3980/j.issn.1672-5123.2014.11.13 doaj:e4600f87583345a49ff1177680f192b0 fatcat:nyebgfirwjfepo4xqwql3vc3le