Sequential peritoneal equilibration test: a new method for assessment and modelling of peritoneal transport
2013
Nephrology, Dialysis and Transplantation
Background. In spite of many peritoneal tests proposed, there is still a need for a simple and reliable new approach for deriving detailed information about peritoneal membrane characteristics, especially those related to fluid transport. Methods. The sequential peritoneal equilibration test (sPET) that includes PET (glucose 2.27%, 4 h) followed by miniPET (glucose 3.86%, 1 h) was performed in 27 stable continuous ambulatory peritoneal dialysis patients. Ultrafiltration volumes, glucose
doi:10.1093/ndt/gfs592
pmid:23413278
fatcat:cpwek4eyefeqbkqp57k2xroyee