A Study on the Air-Conditioning System Using the Floor-Chamber for Residence Part 29 Comparison of Temperature Changes in Air Supply Routes of Different Methods
住宅における床チャンバーを利用した空調に関する研究 (その29)送風方法の違いによる送風経路の温度変化の比較

本間 俊希, 井口 雅登, 蜂巣 浩生, 坂本 雄三
2019 Techinical Papers of Annual Meeting the Society of Heating,Air-conditioning and Sanitary Engineers of Japan  
The heat flows between the floor chambers on the first floor and ground or rooms above the floor cause the temperature change of supply air in the air-conditioning system using the floor-chambers. In this paper, the authors measured temperature of supply air at 3 types of residence, and compared between air supply methods. As a result, the change of the temperature was about 1~2℃ for all types and related the distance of the air supply route in the floor chambers.
doi:10.18948/shasetaikai.2019.6.0_285 fatcat:2hk5oeavevchxm3delymzt32ke