IODINE FLOWSHEET STATUS REPORT [report]

MATTHEW SIEGFRIED, MICHAEL STONE
2020 unpublished
A simplified flowsheet was developed to evaluate the impact of varied assumptions of I-129 decontamination factors on the overall I-129 material balance in the Direct Feed Low-Activity Waste (DFLAW) facility. The flowsheet allows inputs for I-129 feed and Decontamination Factors (DFs) for multiple DFLAW unit operations and provides information on I-129 partitioning to output streams. A series of 6 DFs were evaluated, including baseline DFs from a prior Waste Treatment and Immobilization Plant
more » ... TP) study and refined values based on a Savannah River National Laboratory (SRNL) review. The Microsoft Excel flowsheet spreadsheet will be provided to WRPS to allow further evaluation of the impact of DF assumptions on output streams. The spreadsheet is not specific to iodine, the partitioning of any species can be estimated by entering the assumed DFs for each unit operation. Flowsheet outputs matched results from the prior WTP study and show that different assumptions for the DFs can greatly impact iodine partitioning to primary and secondary waste streams. Results from SRNL's baseline DF values suggest less than 50% of I-129 would be retained in glass versus the 96% when using the BNI DF values. In addition, the flowsheet demonstrated that more than 5 DFLAW operational cycles are required to achieve a steady-state of I-129 to the primary waste stream. It is not possible with the data available to determine whether the BNI approach or the approach taken in this study will be a better match for the iodine partitioning once the LAW facility begins operation.
doi:10.2172/1658844 fatcat:ff3wf57an5bk3fkt3v33nn6ggi