Determination Of Temperature And Velocity Fields In A Corridor At A Central Interim Spent Fuel Storage Facility Using Numerical Simulation
2012
Zenodo
The presented article deals with the description of a numerical model of a corridor at a Central Interim Spent Fuel Storage Facility (hereinafter CISFSF). The model takes into account the effect of air flows on the temperature of stored waste. The computational model was implemented in the ANSYS/CFX programming environment in the form of a CFD task solution, which was compared with an approximate analytical calculation. The article includes a categorization of the individual alternatives for
doi:10.5281/zenodo.1057293