Impacts of Load Profiles on the Optimization of Power Management of a Green Building Employing Fuel Cells
2018
Energies
This paper discusses the performance improvement of a green building by optimization procedures and the influences of load characteristics on optimization. The green building is equipped with a self-sustained hybrid power system consisting of solar cells, wind turbines, batteries, proton exchange membrane fuel cell (PEMFC), electrolyzer, and power electronic devices. We develop a simulation model using the Matlab/SimPowerSystemTM and tune the model parameters based on experimental responses, so
doi:10.3390/en12010057
fatcat:qlvvrb3trrexzce3pjjrtcovka