A Study on Beam-to-Column Connections with Plate Type Energy Absorption System
플레이트형 에너지 흡수장치를 가지는 기둥-보 접합부에 관한 연구

Sang Hoon Oh, Hae Yong Park
2013 Journal of Korean Society of Steel Construction  
Recently, there is a growing interest on sustainable connection system that makes it possible to reuse of main structural members by concentrating most of the damage in the frame caused by strong horizontal force, such as earthquake, to damper. In this study proposed a new type of damage-controlled connection system applying these concepts and analysed the major structural performance of the proposed system through the full-scale cyclic loading test and nonlinear finite element analyses.
more » ... ng to the result, it derived the optimal damper/beam strength ratio that minimize the damage of main members and satisfy at least the fully plastic moment of the beam. And it was to verify the possibility of applying as seismic connection details.
doi:10.7781/kjoss.2013.25.1.103 fatcat:zicedn22rjfeff6e57y75y3p6y