Interturn Fault Diagnosis in Interior Permanent Magnet Synchronous Motors Using Negative-Sequence Impedance
역상 임피던스를 이용한 매립형 영구자석 동기전동기의 권선간 고장진단
2017
The Transactions of The Korean Institute of Electrical Engineers
역상 임피던스를 이용한 매립형 영구자석 동기전동기의 권선간 고장진단
Fault diagnosis is important due to the increasing demand of using interior permanent magnet synchronous machines (IPMSMs). In particular, an interturn fault is one of the most frequent electrical faults in IPMSMs. This paper proposes a fault indicator for diagnosis of interturn faults in IPMSMs. The fault indicator is developed by negative-sequence impedance. The effectiveness of the fault indicator to diagnose interturn faults was verified through various fault conditions.
doi:10.5370/kiee.2017.66.2.394