KALYPSO: Linear Array Detector with Continuous Read-Out at MHz Frame Rates

Christopher Gerth, Bernd Steffen, M. Caselle, L. Rota, Dariusz Makowski, Aleksander Mielczarek
2019
he novel linear array detector KALYPSO has been developed for beam diagnostics based on 1-dimensional profile measurements at high-repetition rate free-electron lasers (FEL) and synchrotron radiation facilities. The current version of KALYPSO has 256 pixels with a maximum frame rate of 2.7~MHz. The detector board, which comprises the radiation sensor, analog signal amplification, and analog-to-digital signal conversion, has been designed as a mezzanine card that can be plugged onto
more » ... pecific carrier boards for data pre-processing and transmission. Either a Si or InGaAs sensor can be mounted for the detection of visible or near infrared radiation. Results obtained in several beam diagnostics applications at the European XFEL and FLASH are presented to demonstrate the powerful capabilities of the KALYPSO detector.
doi:10.3204/pubdb-2019-04512 fatcat:ney2n3cibrhcnelejh266nq744