Performance of the Fast Orbit Feedback System with the Double-Double Bend Achromat Installed in Diamond Light Source
2017
At Diamond Light Source, the Double-Double Bend Achromat (DDBA) lattice upgrade involved the conversion of one cell of the storage ring from a double bend achromat (DBA) structure to a double-DBA (DDBA). The new cell includes corrector magnets that are different in design to the DBA corrector magnets. The DDBA vacuum chamber cross section is also different from the DBA cells and includes both stainless steel and copper sections over which corrector magnets are fitted. The performance of the
doi:10.18429/jacow-ipac2017-tupik113
fatcat:gwgsjmtrxrg4hn67vspjz4vfz4