Effect of the Partial Equilibrium State at the Zirconia Surface in a Cr/Cr2O3-Type Zirconia Oxygen Sensor on Continuous Measurement of the Oxygen Content in Molten Steel
2022
ISIJ International
Zirconia oxygen sensors are used in the steel-refining process to instantly measure the oxygen concentration in molten steel. It is desirable to develop sensors that are capable of continuous and long-time measurements, but such measurements are difficult with conventional sensors. In this study, the factors that hinder long-time measurement by a single zirconia oxygen sensor with a mixture of Cr and Cr 2 O 3 as the reference electrode were investigated. Continuous measurements of a molten iron
doi:10.2355/isijinternational.isijint-2022-058
fatcat:g63awc5uijdr5j7cmvegimkw5q