Numerical Investigations on Detectability of Crack by Contactless jC-Measurement Method

Teruou TAKAYAMA, Atsushi KAMITANI, Hiroaki NAKAMURA
2013 Plasma and Fusion Research  
The inductive method for measuring the critical current density j C and detecting the crack in a hightemperature superconducting (HTS) film have been investigated numerically. To this end, a numerical code has been developed for analyzing the shielding current density in the film with a crack. The results of computations show that the accuracy of the inductive method is degraded remarkably due to the crack. Specifically, it is found that, if the orthographic projection of the coil overlaps with
more » ... the crack, the value of measured j C decreases. This is mainly because the spatial distribution of the shielding current density becomes asymmetry. In conclusion, the crack size and position can be accurately detected by measuring the j C -distribution in the HTS film.
doi:10.1585/pfr.8.2401025 fatcat:ckeib76pmbbxnkbc72l45odq7u