A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2018; you can also visit the original URL.
The file type is application/pdf
.
Analysis of Ultimate Capacity of Prestressed Concrete Bridge with High CFST Piers
2017
DEStech Transactions on Environment Energy and Earth Science
Large span prestressed concrete girder is among the most reasonable bridge structure in the mountainous regions of southwestern China. However, it is particularly challenging to develop efficient solutions for the unpretendingly tall piers in order to across the steep gorges. In this paper, the nonlinear finite element model of the proposed prestressed concrete girder bridge has been developed, and the ultimate capacity of the high piers of concrete filled steel tube was determined by detailed
doi:10.12783/dteees/edep2017/15572
fatcat:bemdaxuf6bhudmsokkasy2gtgu