The anti-corrosion study on the corrosion-sensitive areas of unpainted weathering steel bridges with closed box girder(I)
밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(I)
2013
Corrosion Science and Technology
밀폐 박스거더형 무도장 내후성강 교량의 부식취약부에 대한 방식대책 연구(I)
In corrosion-sensitive areas of exsisting unpainted weathering steel bridges with closed box girder structures. there are some serious local corrosion problems because of rain water or dew water which can not be solved by exsisting maintenance methods. These problems must be controled technically because of bad. influence on the safety of bridge. This study is the first stage of developing the economic corrosion control manual for these local corrosion problems. Through the injection of tar
doi:10.14773/cst.2013.12.3.149
fatcat:ovlld4its5fj7ic4cc2bzdjrea