Thermal Infrared Imagery Integrated with Terrestrial Laser Scanning and Particle Tracking Velocimetry for Characterization of Landslide Model Failure

Junwei Ma, Xiaoxu Niu, Xiao Liu, Yankun Wang, Tao Wen, Junrong Zhang
2019 Sensors  
A laboratory model test is an effective method for studying landslide risk mitigation. In this study, thermal infrared (TIR) imagery, a modern no-contact technique, was introduced and integrated with terrestrial laser scanning (TLS) and particle tracking velocimetry (PTV) to characterize the failure of a landslide model. The characteristics of the failure initiation, motion, and region of interest, including landslide volume, deformation, velocity, surface temperature changes, and anomalies,
more » ... e detected using the integrated monitoring system. The laboratory test results indicate that the integrated monitoring system is expected to be useful for characterizing the failure of landslide models. The preliminary results of this study suggest that a change in the relative TIR signal (ΔTIR) can be a useful index for landslide detection, and a decrease in the average value of the temperature change ( Δ T I R ¯ ) can be selected as a precursor to landslide failure.
doi:10.3390/s20010219 pmid:31906025 fatcat:ucstm7cfh5drplzfci2cqtuuve