Remaining Sites Verification Package for 132-DR-1, 1608-DR Effluent Pumping Station, Waste Site Reclassification Form 2005-035 [report]

R. A. Carlson
2005 unpublished
Area Fence. The facility functioned as a sump to collect radioactively contaminated liquid wastes from the 105-DR Reactor Building. The liquid wastes were collected in the sumps for final disposal by pumping to the 107-DDR Retention Basin via a 41-cm (16-in.)-diarneter pipe. The 1608-DR Effluent Pumping Station consisted of (1) an above-grade structure consisting of concrete block walls, a reinforced concrete floor, and a roof constructed of reinforced concrete deck with composition surface;
more » ... osition surface; and (2) a below-grade structure of reinforced concrete. The facility extended 3.7 m (12 ft) above grade and 9.8 m (32 ft) below grade and was 11 m (36 ft) in length and 10.4 m (34 ft) in width.
doi:10.2172/945039 fatcat:zc6ytpk6w5h3zbaxpsde7fl2ga