A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2019; you can also visit the original URL.
The file type is application/pdf
.
Proposed fault diagnostics of a broken rotor bar induction motor fed from PWM inverter
2016
Journal of Electrical Systems and Information Technology
This paper presents a fault diagnostics technique for a three-phase squirrel cage induction motor. The method is developed using a simplified model affected by bar resistance variation. Based on 3-phase time domain model, the rotor broken bar with different conditions has been simulated to investigate the resulting torque speed characteristic in each condition. The developed fault diagnostics system is capable of identifying the type of the broken-bar faults in the squirrel cage induction machines.
doi:10.1016/j.jesit.2016.07.004
fatcat:irbdkxsienhwxlqjmjqqnidxky