The Effect of Sulfate Anions on Crevice Corrosion in Alloy 22 [report]

G O Ilevbare
2004 unpublished
The electrochemical behavior of Alloy 22 was studied in 4 M NaCl, and 4 M NaCl with sulfate additions of 0.4 and 0.04 M between 45 and 105 o C using Multiple Crevice Assembly (MCA) specimens. The susceptibility to localized corrosion was found to decrease in the presence of sulfate ions in solution.
doi:10.2172/15014767 fatcat:nai52hzbybac5ehtssmugynngm