Resonant characteristics of rectangular hammerhead microcantilevers vibrating laterally in viscous liquid media

Jinjin Zhang, Fabien Josse, Stephen Heinrich, Nicholas Nigro, Isabelle Dufour, Oliver Brand
2013 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC)  
The influence of the beam geometry on the quality factor and resonance frequency of resonant silicon cantilever beams vibrating in their fundamental in-plane flexural mode in water has been investigated. Compared to cantilevers vibrating in their first out-of-plane flexural mode, utilizing the in-plane mode results in reduced damping and reduced mass loading by the surrounding fluid. Quality factors as high as 86 have been measured in water for cantilevers with a 20 μm thick silicon layer.
more » ... on the experimental data, design guidelines are established for beam dimensions that ensure maximal Q-factors and minimal mass loading by the surrounding fluid, thus improving the limit-of-detection of mass-sensitive biochemical sensors. Elementary theory is also presented to help explain the observed trends. Additional discussion focuses on the tradeoffs that exist in designing liquid-phase biochemical sensors using in-plane cantilevers.
doi:10.1109/eftf-ifc.2013.6702240 fatcat:r3wztfgogzejzkw57jofi52snm