A Marx Generator for Exploding Wire Experiments

Rowan Sinton, Ryan van Herel, Wade Enright, Pat Bodger
2011 2011 Asia-Pacific Power and Energy Engineering Conference  
A two-stage Marx generator was designed, constructed and tested for the purpose of investigating long distance exploding wire experiments. The voltage and energy requirements for the experiments are unique; up to 180 kV and 40 kJ is required. Capacitor banks, earthing switches, spark gaps and resistors were purpose-built. Using the completed setup, conductive plasma paths up to 36 m long have been investigated.
doi:10.1109/appeec.2011.5748708 fatcat:3l4adilflnh7ne4ah5wbf7fkea