Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves
밸브 하류에 설치된 건식 초음파유량계의 편차특성

Dong-Keun Lee, Yong Cho
2012 Journal of Fluid Machinery  
This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for
more » ... flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results. † 서 론 관로의 유량측정을 위해 설치된 유량계는 관련법에 따라 주기적으로 편차시험이나 교정을 필하여 사용하여야 한다. 그러나 수도의 특성상 유량계 철거, 교정, 재설치 과정에서 발생하는 단수 등이 수요자에게 불편을 주기 때문에 교정용 기준기는 센서를 관로의 외벽에 부착하여 유량을 측정하는 휴대용초음파유량계를 사용하고 있다. 초음파의 특성은 지 향성이며 투과, 반사, 굴절하기 때문에 고체, 액체, 기체에서 도 그 파동이 잘 전달되고 (1) 관로 내부에 구동부가 없기 때문 에 구조적으로 유지보수가 용이하며 구경이 커져도 센서만 교체하여 측정이 가능하므로 제작비용이 증가하지 않는 장 점이 있으므로 그 적용범위가 해마다 넓어지고 있다. (2) 현재
doi:10.5293/kfma.2012.15.4.012 fatcat:zp5j5imayzalvjeute2a4jdfna