New Arc Stability Index for Industrial AC Three-Phase Electric Arc Furnaces Based on Acoustic Signals
2020
Sensors
This research proposes a new index to evaluate the stability of the melting process, in three-phase electric arc furnaces (EAFs), based on the acoustic signals generated during the different stages of the casting. The proposed stability index is obtained by characterizing the time and frequency domain of the acoustic signals. During EAF monitoring, acoustic signals were acquired using a microphone coupled to an NI USB-9234 acquisition system. To validate the results, the voltage and current
doi:10.3390/s20236840
pmid:33266004
pmcid:PMC7730989