Commentary: Cluster failure: Why fMRI inferences for spatial extent have inflated false-positive rates

Karsten Mueller, Jöran Lepsien, Harald E. Möller, Gabriele Lohmann
2017 Frontiers in Human Neuroscience  
In a recent manuscript, Eklund et al. (2016) reported inflated false positive rates in functional MRI (fMRI) using several common software packages. Here we would like to draw attention to an important aspect that was not addressed in this publication. Specifically, we would like to note that statistical inferences obtained using the random field theory depend heavily on a preprocessing parameter not discussed by Eklund et al. (2016) , namely the spatial resolution to which the data sets are
more » ... ampled and interpolated during pre-processsing. This resampling is needed to align the data to a common anatomical template that is essential to perform group analyses (also often called normalization). Eklund et al. (2016) used the default setting of 2×2×2 mm 3 . In response to Eklund's paper, Flandin and Friston (2016) used a different setting of this parameter, namely 3×3×3 mm 3 . Together with a more stringent initial cluster-forming threshold, they did not observe inflated false positive rates. However, the 2×2×2 mm 2 setting is the default in two major software packages (SPM, FSL), and in previous work, Friston and colleagues Hopfinger et al. (2000) stated that resampling to 2×2×2 mm 3 renders the analysis "more sensitive." In other words, at present it is unclear what a valid setting for this parameter should be. Therefore, we think that it is extremely relevant to assess its influence on statistical inference. For this purpose, we analyzed a group of 47 resting-state fMRI data sets with a spatial resolution of 3×3×4 mm 3 and 300 volumes used in a preceding study Mueller et al. (2016) . Using a strategy analogous to Eklund et al. (2016) we imposed various fake designs including block-and eventrelated types. We tested the following resampling parameters: 3×3×4, 3×3×3, 2×2×2, and 1×1×1 mm 3 . Using SPM12 with family-wise error (FWE) correction based on the random field theory, we first evaluated each data set separately. We found that with higher resampling resolutions, the FWEcorrected p-values decrease systematically so that more and more false positives occur. Figure 1A shows a typical result. We obtained a systematic effect in all of the 47 data sets (Figure 1B) . We also observed a systematic effect of image upscaling onto smoothness estimation ( Figure 1C) . Furthermore, we performed a group-level inference in which all 47 data sets were pooled. Again, we observed that the FWE-corrected p-values decreased systematically with higher resampling resolutions.
doi:10.3389/fnhum.2017.00345 pmid:28701944 pmcid:PMC5487467 fatcat:sq5ldufalfgwtoragatitb4s2y