Figure 2 from: Zrodnikov AV, Dekusar VM, Gurskaya OS (2021) System levelized fuel cost of electricity generation in a two-component nuclear energy system with a closed uranium-plutonium NFC. Nuclear Energy and Technology 7(4): 303-309. https://doi.org/10.3897/nucet.7.78367
[component]
2021
unpublished
The authors propose an approach to the calculation of the levelized unit fuel cost (LUFC) of electricity generation for a fast reactor in a two-component nuclear energy system (NES) with regard for plutonium production. The approach is based on taking into account the additional economic effect, which can be achieved through the sale at the market price of the natural uranium released due to the substitution of thermal reactors by fast reactors with MOX fuel based on the plutonium bred in a
doi:10.3897/nucet.7.78367.figure2
fatcat:gs34eeiipfcalen3ftgg5g6lyy