Radiotherapy planning using MRI

Maria A Schmidt, Geoffrey S Payne
2015 Physics in Medicine and Biology  
Dosimetric feasibility of magnetic resonance (MR)-based dose calculation of prostate radiotherapy using multilevel threshold algorithm Turki Almatani et al -This content was downloaded from IP address 54.70.40.11 on 18/10/2017 at 22:35 Abstract The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also
more » ... considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT. of Urogenital R 2012 ESUR prostate MR guidelines 2012 Eur. Radiol. 22 746-57 Barillot I and Reynaud-Bougnoux A 2006 The use of MRI in planning radiotherapy for gynaecological tumours Cancer Imag. 6 100-6 Barkati M, van Dyk S, Foroudi F and Narayan K 2010 The use of magnetic resonance imaging for image-guided brachytherapy J. Med. Imag. Radiat. Oncol. 54 137-41 Bauman G, Haider M, van der Heide U A and Menard C 2013 Boosting imaging defined dominant prostatic tumors: a systematic review Radiother. Oncol. 107 274-81 Bedford J L, Convery H M, Hansen V N and Saran F H 2012 Paraspinal volumetric modulated arc therapy Br. J. Radiol. 85 1128-33 Bhide S A, Ahmed M, Barbachano Y, Newbold K, Harrington K J and Nutting C M 2008 Sequential induction chemotherapy followed by radical chemo-radiation in the treatment of locoregionally advanced head-and-neck cancer Br. J. Cancer 99 57-62 Blackall J M, Ahmad S, Miquel M E, McClelland J R, Landau D B and Hawkes D J 2006 MRIbased measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning Phys. Med. Biol. 51 4147-69 Bowes D, Crook J M, Rajapakshe R, Araujo C and Parker B 2013 Defining a magnetic resonance scan sequence for permanent seed prostate brachytherapy postimplant assessment Brachytherapy 12 25-9 Braendengen M, Hansson K, Radu C, Siegbahn A, Jacobsson H and Glimelius B 2011 Delineation of gross tumor volume (GTV) for radiation treatment planning of locally advanced rectal cancer using information from MRI or FDG-PET/CT: a prospective study Int. J. Radiat. Oncol. Biol. Phys. 81 e439-45 Brix L, Ringgaard S, Sorensen T S and Poulsen P R 2014 3D liver motion tracking using real-time 2D MRI Med. Phys. 41 042302 Brock K K and Dawson L A 2010 Adaptive management of liver cancer radiotherapy Semin. Radiat. Oncol. 20 107-15 Buis D R, Lagerwaard F J, Dirven C M, Barkhof F, Knol D L, van den Berg R, Slotman B J and Vandertop W P 2007 Delineation of brain AVMs on MR-angiography for the purpose of stereotactic radiosurgery Int. J. Radiat. Oncol. Biol. Phys. 67 308-16 Burgos N et al 2013 Attenuation correction synthesis for hybrid PET-MR scanners Med. Image Comput. Comput. Assist. Interv. 16 147-54 Butts K, Pauly J M and Gold G E 2005 Reduction of blurring in view angle tilting MRI Magn. Reson. Med. 53 418-24 Calamante F 2010 Perfusion MRI using dynamic-susceptibility contrast MRI: quantification issues in patient studies Top. Magn. Reson. Imag. 21 75-85 Calcerrada Diaz-Santos N, Blasco Amaro J A, Cardiel G A and Andradas Aragones E 2008 The safety and efficacy of robotic image-guided radiosurgery system treatment for intra-and extracranial lesions: a systematic review of the literature Radiother. Oncol. 89 245-53 Callaghan P T 1991 Principles of Nuclear Magnetic Resonance Microscopy (Oxford: Clarendon) Caramanos Z, Fonov V S, Francis S J, Narayanan S, Pike G B, Collins D L and Arnold D L 2010 Gradient distortions in MRI: characterizing and correcting for their effects on SIENA-generated measures of brain volume change Neuroimage 49 1601-11 Chang H and Fitzpatrick J M 1992 A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities IEEE Trans. Med. Imag. 2014 MRI scans significantly change target coverage decisions in radical radiotherapy for prostate cancer J. Med. Imag. Radiat. Oncol. 58 237-43 Choi H and Ma J 2008 Use of perfluorocarbon compound in the endorectal coil to improve MR spectroscopy of the prostate AJR Am. J. Roentgenol. 190 1055-9 Chong I, Hawkins M, Hansen V, Thomas K, McNair H, O'Neill B, Aitken A and Tait D 2011 Quantification of organ motion during chemoradiotherapy of rectal cancer using cone-beam computed tomography Int. J. Radiat. Oncol. Biol. Phys. 81 e431-8 Creak A L, Tree A and Saran F 2011 Radiotherapy planning in high-grade gliomas: a survey of current UK practice Clin. Oncol. (R. Coll. Radiol.) 23 189-98 Crijns S P, Raaymakers B W and Lagendijk J J 2011 Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy Phys. Med. Biol. 56 289-97 Topical Review Phys. Med. Biol. 60 (2015) R323 Topical Review Phys. Med. Biol. 60 (2015) R323 Topical Review Phys. Med. Biol. 60 (2015) R323 R355 Johansson A, Garpebring A, Asklund T and Nyholm T 2014 CT substitutes derived from MR images reconstructed with parallel imaging Med. Phys. 41 082302 Johansson A, Karlsson M and Nyholm T 2011 CT substitute derived from MRI sequences with ultrashort echo time Med. Phys. 38 2708-14 Jolicoeur M, Racine M L, Trop I, Hathout L, Nguyen D, Derashodian T and David S 2011 Localization of the surgical bed using supine magnetic resonance and computed tomography scan fusion for planification of breast interstitial brachytherapy Radiother. Oncol. 100 480-4 Jones D (ed) 2011 Diffusion MRI: Theory, Methods and Applications (New York: Oxford University Press) Jonsson J H, Garpebring A, Karlsson M G and Nyholm T 2012 Internal fiducial markers and susceptibility effects in MRI-simulation and measurement of spatial accuracy Int. J. Radiat. Oncol. Biol. Phys. 82 1612-8 Jonsson J H, Johansson A, Soderstrom K, Asklund T and Nyholm T 2013 Treatment planning of intracranial targets on MRI derived substitute CT data Radiother. Oncol. 108 118-22 Jovicich J et al 2006 Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data Neuroimage 30 436-43 Kapanen M, Collan J, Beule A, Seppala T, Saarilahti K and Tenhunen M 2013 Commissioning of MRIonly based treatment planning procedure for external beam radiotherapy of prostate Magn. Reson. Med. 70 127-35 Kapanen M and Tenhunen M 2013 T1/-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning Acta Oncol. 52 612-8 Karotki A, Mah K, Meijer G and Meltsner M 2011 Comparison of bulk electron density and voxel-based electron density treatment planning J. Appl. Clin. Med. Phys. 12 3522 First MRI application of an active breathing coordinator Phys. Med. Biol. 60 1681-96 Kennan R P and Jager H R 2003 T2-and -w DCE-MRI: blood perfusion and volume estimation using bolus tracking Quantitative MRI of the Brain ed P S Tofts (New York: Wiley) Khoo V S, Dearnaley D P, Finnigan D J, Padhani A, Tanner S F and Leach M O 1997 Magnetic resonance imaging (MRI): considerations and applications in radiotherapy treatment planning Radiother. Oncol. 42 1-15 Kim Y, Hsu I C, Lessard E, Kurhanewicz J, Noworolski S M and Pouliot J 2008 Class solution in inverse planned HDR prostate brachytherapy for dose escalation of DIL defined by combined MRI/MRSI Radiother. Oncol. 88 148-55 Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: I. Correlating internal lung motion with skin fiducial motion Int. J. Radiat. Oncol. Biol. Phys. 60 1459-72 Koga T et al 2012 Outcomes of diffusion tensor tractography-integrated stereotactic radiosurgery Int. J. Radiat. Oncol. Biol. Phys. 82 799-802 Koh D M, Brown G and Collins D J 2009 Nanoparticles in rectal cancer imaging Cancer Biomark. 5 89-98 Korsholm M E, Waring L W and Edmund J M 2014 A criterion for the reliable use of MRI-only radiotherapy Radiat. Oncol. 9 16 Kovacs A, Toth L, Glavak C, Lakosi F, Hadjiev J, Bajzik G, Vandulek C and Repa I 2011 Integrating functional MRI information into radiotherapy planning of CNS tumors-early experiences Pathol.
doi:10.1088/0031-9155/60/22/r323 pmid:26509844 pmcid:PMC5137785 fatcat:i43hzqxdafhvtck2pblilloirq