Distributed Generation Control Using Modified PLL Based on Proportional-Resonant Controller
2020
Applied Sciences
Due to the increasing necessity for electrical demand, the microgrids (MGs) based on distributed generations (DGs) within power electronic interfaces are being extended to improve the traditional network control. One of the common ways to achieve power sharing among the resources on an islanding MG is to use the droop control approach, performing based on proportional-integrator (PI) controllers. However, due to the effect of feeder impedance, obtaining the reactive power sharing using this
doi:10.3390/app10248891