Modelling and Thermal Analysis of Advanced Insulating Layer of Electronic Applications

Steffen Klarmann, Yuriy Vagapov, Heinrich Gotzig
2018 2018 24rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)  
This paper proposes the replacement of a conventional Insulating-Metal-Substrate (IMS) dielectric layer with an electroconductive adhesive which is applied onto a treated aluminium heat sink. The adhesive based structure results in a lower thermal resistance of the system compared to IMS based on Aluminium. The model covers the investigation of two IMS structure with a Copper conductor layer with a thickness of 200µm, a dielectric layer of 50µm with different thermal conductivities and an
more » ... ium base layer with a thickness of 920µm. However, the IMS is placed onto a 100 x 100 x 33 mm Aluminium heat sink. The investigated adhesive based structure consists of the same Aluminium heat sink treated with an oxidation layer with a thickness of 50µm and an adhesive conductor layer with 30µm thickness. Furthermore, the use of forced convection to reduce the junction temperature of all three models is also considered.
doi:10.1109/therminic.2018.8593297 fatcat:agew6q3amvcjvjrdyfpwfrewiq