Calculation on cosmic-ray muon exposure rate in non-walled concrete buildings

Kazunobu FUJITAKA, Siro ABE
1984 RADIOISOTOPES  
Computer simulations on the exposure indoors from cosmic ray muons were practiced in the framework of non-scattering and non-cascade assumptions. The model buildings were two-dimensional, rectangular, and were made of a normal concrete. A stratified structure was assumed in each building, where no mezzanine was considered. Walls were not taken into account yet. The distributions of the exposure rates in 26-story buildings were illustrated in contour maps for various sets of parameters. All of
more » ... em gave basically archlike patterns. Analyses of the results showed that the exposure rate is affected most largely by the floor board thickness. The ceiling height would be an insignificant factor for short buildings. The min/max ratio of the muon exposure rate in a moderate size building was estimated to be more than 0.7.
doi:10.3769/radioisotopes.33.6_350 fatcat:ife33z7y4vcthl7sreakow7mjq