Influence of Underground Water Quality Adjacent to Landfill Site on Hydrogeologic Characteristics of LPG Storage Cavern
매립장 인근 지하수질이 LPG 저장 공동의 수리지질학적 특성에 미치는 영향

Won-Gyu Choi
2014 Journal of Digital Convergence  
The underground water quality of petroleum products storage cavern is influenced by that of dumping and landfill sites adjacent to cavern. From the chemical analysis of underground water sampled from landfill site, insignificant amounts of As, Cu and Pb were detected in a half of test samples while Cd, Hg, Cr 6+ , CN -, TCE, PCE and Phenol were not detected in all samples. All measurements of COD Mn were below 8.0㎎/ℓ that can be negligible for the contamination by organic matters. The total
more » ... eria counted from 1st and 2nd microbiological analysis were 94.84x10 4 cells/㎖ and 146.26x10 -4 cells/㎖, respectively, and all counts of the sulfate reducing bacteria were less than 2cells/㎖. It can be suggested that the water quality adjacent to storage cavern can also be studied to improve the reliability of hydrogeologic stability of storage cavern. 요 약 석유 제품 지하 저장 공동의 지하수 수질은 공동 인근 매립지 수질의 영향을 받는다. 매립지 주변의 지하수 수질 분석 결과, 시료의 반 정도에서 지하공동 수질에 영향이 미미한 농도의 As, Cu 및 Pb가 검출되었으며, Cd, Hg, Cr 6+ , CN -, TCE, PCE 및 Pheno은 검출되지 않았다. COD Mn 의 농도는 모든 시료에서 8.0㎎/ℓ이하로 유기물질에 의한 지하수 오염은 거의 없는 것으로 분석되었다. 1차, 2차 미생물 분석결과 총박테리아는 각각 94.84x10 4 cells/㎖ 과 146.26x10 -4 cells/㎖이고 황산환원 박테리아는 2cells/㎖이하로 분석되어 지하공동의 수질에 영향이 미미할 것으로 분석되었다. 저장 공동 인근 지역의 지하수 수질 분석은 공동의 수리 지질의 안정성을 향상시키기 위하여 지속적인 조사와 관리가 필요할 것으로 판단된다.
doi:10.14400/jdc.2014.12.8.283 fatcat:illgwnk3endgznaa37yl4fipda