Studies on Porcelain-Facing Alloys for Conical Double-Crown Telescopic Prothesis. Part 1. Change of Physical Properties with Addition of Titanium in Cobalt Chrome Alloys
ポーセレン前装コーヌス・テレスコープ用合金に関する研究 第1報 コバルト・クロム合金へのチタン添加による物理的性質について

Michitsugu Bandai, Akihiko Shiba, Tadashi Matsuyama, Michihisa Urita, Kazuya Oyanagi, Seiko Komatsu, Ken Nohara, Masahiro Fujiwara
1993 Nihon Hotetsu Shika Gakkai Zasshi  
The purpose of this study was to investigate the physical properties of Co-Cr alloys containing 0-10% titanium. The results were as follows : The solid and liquid temperature fell, the specific gravity decreased and the oxidation was repressed with addition of titanium. The value of Vickers hardness increased with addition of 4% upward titanium. The maximum contraverse strength value was shown in 4% titanium alloy. The maximum tensile stregnth value was shown in 6% titanium alloy. The maximum elongation value was shown in 2% titanium alloy.
doi:10.2186/jjps.37.989 fatcat:nhztkiu6vzciziskf4pmyp34xe