Rejection of randomly coinciding events in ZnMoO $$_4$$ 4 scintillating bolometers

D. M. Chernyak, F. A. Danevich, A. Giuliani, M. Mancuso, C. Nones, E. Olivieri, M. Tenconi, V. I. Tretyak
2014 European Physical Journal C: Particles and Fields  
Random coincidence of events (particularly from two neutrino double beta decay) could be one of the main sources of background in the search for neutrinoless double beta decay with cryogenic bolometers due to their poor time resolution. Pulse-shape discrimination by using front edge analysis, mean-time and χ^2 methods was applied to discriminate randomly coinciding events in ZnMoO_4 cryogenic scintillating bolometers. These events can be effectively rejected at the level of 99 of about 14 ms
more » ... signal-to-noise ratio of 900, and at the level of 92 analysis of the light signals with rise-time of about 3 ms and signal-to-noise ratio of 30, under the requirement to detect 95 rejection efficiencies are compatible with extremely low background levels in the region of interest of neutrinoless double beta decay of ^100Mo for enriched ZnMoO_4 detectors, of the order of 10^-4 counts/(y keV kg). Pulse-shape parameters have been chosen on the basis of the performance of a real massive ZnMoO_4 scintillating bolometer. Importance of the signal-to-noise ratio, correct finding of the signal start and choice of an appropriate sampling frequency are discussed.
doi:10.1140/epjc/s10052-014-2913-4 fatcat:nqnni7zgljf6tdoraythisonke