MP629DETERMINANTS OF INTRAOPERATIVE BLOOD FLOW OF AUTOLOGOUS RADIOCEPHALIC ARTERIOVENOUS FISTULA AT THE TIME OF FISTULA CONSTRUCTION

Young Rim Song
2017 Nephrology, Dialysis and Transplantation  
Introduction. Arteriovenous fistula (AVF) is the best access for hemodialysis. The failure of arteriovenous fistula maturation is currently a major problem faced today. This study aims to assess whether an intraoperative blood flow rate measured with Doppler ultrasound can be a predictor of the maturity of radiocephalic AVF. Method. Subjects were patients to be made radiocephalic AVF with USG mapping according to the standard. Shortly after, the anastomosis blood flow rate was measured with a
more » ... s measured with a linear probe Doppler ultrasound. This study used a cross-sectional analytic design to obtain radiocephalic AVF maturation relationship with intraoperative blood flow rate. Results. Radiocephalic AVF (n = 71) in 71 patients were made and evaluated in 6 weeks. The mean intraoperative blood flow rate in mature fistulas was significantly higher than those which did not mature (201.85 and 141.96 mL/min; p <0.001). The blood flow rate with a cut-off value of 165.5 mL/min has a sensitivity of 93.8%, specificity 95.7%, positive predictive value 97.8% and negative predictive value 88.5%. Conclusion. Blood flow rate >165.5 mL/min has a good predictor value for radiocephalic AVF maturation. Thus, it can be used as a reference to determine whether the surgeon needs for further assessment and revision intraoperatively, which in turn is expected to decrease the maturation failure rate of arteriovenous fistula.
doi:10.1093/ndt/gfx178.mp629 fatcat:walbnwzwu5bopjonunbo4k6sm4