Mathematical Modeling Of An Amperometric Glucose Sensor: The Effect Of Membrane Permeability And Selectivity On Performance

Azila Abd. Aziz
2009 Jurnal Teknologi  
Interference from electro-active chemicals such as ascorbic acid, uric acid and acetaminophen can be a problem for peroxide based glucose biosensors. Most works focused on the employment of a perm-selective membrane sandwiched between the electrode and the active component of the sensor to overcome this problem. In this work, a mathematical model has been developed to study the effect of membrane permeability and selectivity on peroxide based glucose biosensor performance. Digital simulation
more » ... carried out using the finite difference method. As expected, membrane selectivity to peroxide played a major role in interference reduction. However, interestingly, the model also suggested that the manipulation of the transport properties of the protective outer layer would also result in acceptable interference reduction. Abstrak. Gangguan dari bahan kimia elektro-aktif seperti asid askorbik, asid urik dan asetaminofen adalah merupakan satu masalah bagi biosensor glukosa berasaskan peroksid. Kebanyakan kerja penyelidikan memfokuskan kepada penggunaan membran yang perm-selektif di antara elektrod dan komponen aktif sensor untuk menghilangkan masalah ini. Dalam kerja penyelidikan ini, satu model matematik telah dibina untuk mengkaji kesan kebolehtelapan dan kememilihan bagi prestasi biosensor glukosa berasaskan peroksid. Simulasi digital telah dijalankan menggunakan kaedah pembezaan terhingga. Seperti yang dijangka, kememilihan membran kepada peroksid memainkan peranan besar dalam mengurangkan gangguan. Namun begitu, model juga mencadangkan yang manipulasi sifat pengangkutan lapisan pelindung luar boleh juga menghasilkan keputusan yang memberangsangkan dalam mengurangkan gangguan.
doi:10.11113/jt.v51.148 fatcat:jjvsep47hnelrn7o7s4crnhtca