Determinação de bifenilos policlorados em soro de cordão umbilical através de extração por hidrólise ácida seguida de cromatografia a gás acoplada a um microdetector de captura de elétrons

Susana Mohr, Thiago Guilherme Schwanz, Roger Wagner, Leandra Soldatelli, Ijoni Hilda Costabeber
2011 Química Nova  
The present work describes the determination of polychlorinated biphenyls in 123 umbilical cord serum samples by liquid-liquid extraction method with acid hydrolyze step and analysis by GC-µECD. The analytical method was evaluated with following figures of merit for all PCBs: linearity (>0.997); precision (<12.55%); recoveries (73-119%); limit of detection (0.1 ng mL -1 ); limit of quantification (0.25-0.5 ng mL -1 ). The results showed high contamination in the analyzed samples. PCB more
more » ... nt was 138 (66.7%), followed by 180 (55.3%) and 52 (51.3%).
doi:10.1590/s0100-40422011000300015 fatcat:uriwfi6gcvdxtneb74xwuourca