Calculation of temperature field of coiled wire using EFM
2018
E3S Web of Conferences
Provided a heat transfer model of coiled wire method. Based on the method, a software of EFM (ANSYS) was used to calculate the temperature field of coiled wire. Comparisons between the experimental of RVS coiled wire and numerical results indicated the effectiveness of the method utilized. The simulation method based on EFM proved to be useful for the fire risk assessment of coiled wire.
doi:10.1051/e3sconf/20187203002