Influence of Mirrors utilization on the Radiation Emitted by Models Subjected to Hypersonic Flow for Surface Temperature Determination

F. De Filippis, C. Toscano, D. Gallo, P. Caruso, L. Savino
2012 Proceedings of the 2012 International Conference on Quantitative InfraRed Thermography   unpublished
This work focuses on the specific application of Infrared Thermography (IRT) during plasma wind tunnel tests that reproduce hypersonic gas conditions performed in CIRA Scirocco facility. Unfortunately some drawbacks can limit the use of the thermographic set up in Scirocco in some specific nozzle configurations, because it is impossible to obtain a direct view of the test model from the thermal camera. These difficulties are overcome by using a mirror, which, on the contrary, provides a non
more » ... ct view of the model by the thermal camera. The present work shows that classical mirrors (with reflectivity across the entire visible spectrum) can represent a simple and cheap way to measure the target temperature in these critical geometric conditions. http://dx.