Corrosion Resistance of Cr-bearing Rebar to Macrocell Corrosion Caused by Concrete Cover Crack

Sung-Ho Tae, Han-Seung Lee, Takafumi Noguchi, Takumi Ujiro, Sung-Woo Shin
2006 ISIJ International  
Artificial cracks were made in the cover concrete of specimens embedding ten types of steel rebars having different Cr contents with the aim of developing Cr-bearing steel rebars resistant to macrocell corrosion environments induced by cracking in cover concrete. The cracks were subjected to intensive penetration of carbon dioxide (carbonation specimens) and chloride ions (chloride attack specimens) to form macrocells. Both groups of specimens were then subjected to accelerated corrosion
more » ... during which the macrocell corrosion current density was measured. The corrosion area and corrosion loss were also measured at the end of 105 cycles of this accelerated curing. In a macrocell corrosion environment induced by localized carbonation, the minimum Cr content of rebars required for corrosion resistance was 7 %. Rebars with a Cr content of 11 % were proven corrosion-resistant in a chloride ion concentration macrocell with a concentration difference of not more than 3 kg/m 3 .