Model-Free Current Loop Autotuning for Synchronous Reluctance Motor Drives
2020
Automation
Synchronous reluctance motors are arousing lively interest as a possible alternative to the less efficient induction motors. An open issue is the effective tuning of the inner current loops because of the nonlinearity that cannot be overlooked. The present paper uses a relay feedback approach to perform autotuning without resorting to any parameter knowledge. The tuning is iterated at different working points, to get a uniform current control bandwidth everywhere. Unlike many solutions in the
doi:10.3390/automation1010003
fatcat:qxlrttyo6rc6zh3dcnontnkxj4