Performance of BIPV and BAPV installations in Norway

Anne Gerd Imenes
2017 2017 IEEE 44th Photovoltaic Specialist Conference (PVSC)  
Large scale implementation of PV in urban areas asks for more shadow tolerant modules and more size flexibility. Power optimizers and micro inverters can be used to improve shadow tolerance of standard c-Si modules but the electrical interconnection and the size of cell groups in the standard module design is a limiting factor when it comes to further increase shadow tolerance. In this work another approach is used in which the cells in the module are smaller and series connected in building
more » ... cks. The resulting lower currents allow the use of small in laminate diodes and the building blocks give access to more size flexibility and improved shadow robustness. Yearly yield calculations will be shown and compared to a standard 3sub-string module with either power optimizers or micro inverters. It is shown that for a typical Dutch house the TESSERA concept outperforms the other by up to 6%.
doi:10.1109/pvsc.2017.8366744 fatcat:xlux6bflzraarptkfsyn675btm