Monitoring sessile droplet evaporation on a micromechanical device
2014
The Analyst
A bulk acoustic mode micro-electro-mechanical dual resonator platform is utilised to study the evaporation of sub-microliter water droplets from the surface of the resonator. An analytical formulation for the observed frequency shift and the measure dependence of resonant frequency on the modes of evaporation which is consistent with the optically derived data. The resonators access only a thin layer of the liquid through shear contact and, hence, the response is not affected by the bulk mass
doi:10.1039/c4an01389a
pmid:25199661
fatcat:xb6jd3f7mzep5hdcr5k4eaqqym