Simple Measurement of the AC Transport Current Loss for HTS Conductors Using an Active Power Detection Method
有効電力法による高温超電導線材の交流損失の簡易測定
2005
TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
有効電力法による高温超電導線材の交流損失の簡易測定
Synopsis: Reducing AC loss in superconducting apparatus is one of the most important issues, and the precise measurement and estimation of AC losses are essential to reduce them. The four-terminal method is universally used as an electric measurement method of AC losses for superconducting tapes and wires. In this method, noise and inductive voltage superposed on the terminal voltage of the superconductor are eliminated by a lock-in amplifier and cancel coil, respectively, and then measurement
doi:10.2221/jcsj.40.420