Study on the Direct Tensile Test for Cemented Soils Using a Built-In Cylinder
내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구
2014
Journal of the Korean Society of Civil Engineers
내장형 실린더를 이용한 시멘트 고결토의 인장시험 방법에 관한 연구
In this study, a cylinder embedded within cemented soils was used to cause directly tensile failure of cemented soils. An existing dumbbell type direct tensile test and a split tensile test that is most general indirect tensile test were also carried out to verify the developed built-in cylinder tensile test. Testing specimens with two different sand/cement ratios (1:1 and 3:1) and two curing periods (7 and 28 days) were prepared and tested. Total 10 specimens were prepared for each case and
doi:10.12652/ksce.2014.34.5.1505