Shear Resistance of CIP Anchors under Dynamic Loading: Unreinforced Anchor

Moon Ki Kang
2014 Journal of Korean Society of Steel Construction  
The Concrete Capacity Design(CCD) method has been used in the design of anchor since 2001 and Korean design code specify that concrete breakout capacity of CIP anchor under seismic load shall be taken as 75% of static capacity. In this study, an experimental study was performed to evaluate the concrete breakout capacity of unreinforced CIP anchors under dynamic shear force. For the purpose, three static and dynamic shear-loading tests were conducted using 20mm diameter anchors, respectively.
more » ... edge distance of 120mm was considered in the tests. In the dynamic tests, 15 cycles pulsating load with 1Hz speed was applied and the magnitude of loading step was increased until concrete breakout failure occurs. From the tests, the concrete breakout capacity under dynamic shear loading showed nearly same capacity by static loading.
doi:10.7781/kjoss.2014.26.1.011 fatcat:hlddqkwnebf5xlzsqc34mcvwtu