Location and correction of 60 hz in the CEBAF injector [report]

R. Legg, D. Douglas, G.A. Krafft, Q. Saulter
1996 unpublished
CEBAF produces a continuous electron beam with an emittance of 2-3 nm-Rad. Transverse low frequency magnetic oscillations act to dilute this emittance. These fields are typically associated with AC line conductors. The CEBAF injector is approximately 40 m long. To locate the source(s) of the beam motion, measured offsets were back propagated along the beamline using the DIMAD model. Field measurements were then made at the calculated field source positions and correlated with the measured
more » ... s. Corrections and final beam measurements were made to ver@ the corrections.