Reference and Interpretive Ranges for α1-Antitrypsin Quantitation by Phenotype in Adult and Pediatric Populations

Leslie J. Donato, Sarah M. Jenkins, Carin Smith, Jerry A. Katzmann, Melissa R. Snyder
2012 American Journal of Clinical Pathology  
A b s t r a c t Laboratory evaluation of α 1 -antitrypsin (A1AT) deficiency involves measurement of circulating A1AT protein (quantitation) and characterization of A1AT genetic polymorphisms (phenotyping or genotyping). This study compared adult and pediatric A1AT reference ranges in patients with nondeficiency alleles and examined A1AT concentrations in multiple other phenotypes. A1AT phenotype and quantitation were retrospectively collected on adult (n = 21,444) and pediatric (n = 2,469)
more » ... ic (n = 2,469) samples that were submitted for laboratory evaluation of A1AT deficiency. The 95% reference ranges for normal adult and pediatric populations with the M/M phenotype were determined to be 100 to 273 mg/dL (18.4-50.2 μmol/L) and 93 to 251 mg/dL (17.1-46.2 μmol/L), respectively (P < .0001). Decreased concentrations of A1AT correlated with heterozygosity and homozygosity for the S and Z alleles in both the adult and pediatric groups. Other rare alleles, such as I, were also associated with decreased concentrations of A1AT, particularly in the context of a Z allele, and may warrant monitoring for symptoms of deficiency. Upon completion of this activity you will be able to: • define the testing parameters and expected results for the laboratory evaluation of a 1 -antitrypsin (A1AT) deficiency. • interpret A1AT test results used for the evaluation of patients with suspected A1AT deficiency.
doi:10.1309/ajcpmeejk32acyfp pmid:22912357 fatcat:3g5sebsjkzd4rfhywzub7s6jp4