Analysis of Model Predictive Current-Controlled Permanent Magnet Synchronous Motor Drives with Inaccurate DC Bus Voltage Measurement
2020
Energies
In this paper, the effects of inaccurate DC bus voltage measurement are analyzed to model predictive current-controlled permanent magnet synchronous motor (PMSM) drives. It is found that the selection of the optimal space vector is affected by inaccurate DC bus voltage measurements, and the shortest distance principle is proposed to evaluate the effects. With the under-voltage measurement, the actual q axis current is always larger than the reference value, and PMSM may be damaged by the