Seismic analysis using virtual mass method for double cylindrical structure containing liquid
仮想流体質量法を用いた二重円筒構造物の耐震解析
2016
The Proceedings of Mechanical Engineering Congress Japan
仮想流体質量法を用いた二重円筒構造物の耐震解析
The purpose of this study is to evaluate the effect of fluid on structure. The previous our report developed analysis flow using virtual mass methoad of MSC Nastran for fluid modeling. This study focused on double cylindrical structure which was intended for verification problem in the previous our report, and suppression pool in advanced boiling water reactor (ABWR) nuclear power plant was selected as the target structure, three-dimensional finite element model of the ABWR building with large
doi:10.1299/jsmemecj.2016.j1010202