A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2020; you can also visit the original URL.
The file type is application/pdf
.
Cracking in Concrete near Joints in Steelconcrete Composite Slab / Zarysowanie Płyty Żelbetowej W Strefie Przywęzłowej Stropu Zespolonego
2015
Civil and Environmental Engineering Reports
In this paper results of the experimental tests of four full-scale composite steel-concrete elements are reported. In the steel-concrete composite elements, a steel beam was connected with a slab cast on profiled sheeting, by shear studs. The end-plates were (the thickness of 8 mm, 10 mm and 12 mm) thinner than in ordinary design. Joints between the column and the beams have been designed as semi-rigid, i.e. the deformations of endplates affect the distribution of forces in the adjacent parts
doi:10.1515/ceer-2015-0013
fatcat:olhnl3tc7rhebkitguo5tgrzfa