Delayed Failure Test of Synthetic Heat-Affected Zone of High-Strength Steel due to Hydrogen
高張力鋼溶接熱サイクル再現試験片の水素による遅れ破壊試験について

Harumasa Nakamura, Michio Inagaki
1969 JOURNAL OF THE JAPAN WELDING SOCIETY  
A delayed failure test was done with notched specimens of synthetic heat-affected zone of highstrength steel. The test method was a so-called "charge and stress method, in which the specimen was subjected, at first, to a weld thermal cycle, charged with hydrogen electrolytically and then loaded in sustained manner. The main conclusions obtained in the study are as follows: (1) Root crack susceptibility of the heat-affected zone in the first layer weld of a low-alloy high-strength steel can be
more » ... amined in the delayed failure test of the synthetic heat-affected zone of steel.
doi:10.2207/qjjws1943.38.9_1021 fatcat:o5huttoy7vhj5mkopccrfusfsy