Investigation and Comparison of Three-Phase and Six-Phase Cage Motor Energy Parameters

Jonas Buksnaitis
2015 Elektronika ir Elektrotechnika  
Factory-produced three-phase 2,2 kW power cage motor with single-layer preformed winding and the same motor after its original winding was replaced with a singlelayer preformed six-phase winding was investigated in this work. Electromagnetic properties of the stator windings of the analysed motors were determined after performing the harmonic analysis of rotating magnetomotive forces generated by them and by calculating the electromagnetic efficiency factors according to the results of this
more » ... results of this analysis. Electromagnetic efficiency factors of both single-layer preformed three-phase and six-phase windings are equal under the same pole count but unequal number of pole and phase slots (kef = 0,914). All energy parameters of factory-made cage motor and rewound motor were calculated after completing their no-load and load tests and by using the segregated-losses method. It was estimated that under the rated load the phase electric current of rewound cage motor containing a six-phase stator winding decreased by 16,4 %, power input from electric grid decreased by 4,4 %, power losses decreased by 13,5 %, efficiency factor increased by 3,8 %, and power factor increased by 4,7 %, compared to identically loaded factory-made cage motor with respective energy parameters. Research has shown that energy parameters of the six-phase cage motor were noticeably better compared to the three-phase motor, even though the electromagnetic efficiency factors of their windings were equal. Index Terms-Analysis, induction machine, multi-phase system, single-layer former winding, electromagnetic efficiency factor, energy parameters, performance characteristics. http://dx.
doi:10.5755/j01.eee.21.3.5876 fatcat:ku75t4mve5dbdbk63vkz7tm3ue